CVE-2025-54923 (CNNVD-202508-2258)
中文标题:
Schneider Electric EcoStruxure Power Monitoring Expert和EcoStruxure Power Operation AdvancedReporting and Dashboards Module 代码问题漏洞
英文标题:
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code executi...
漏洞描述
中文描述:
Schneider Electric EcoStruxure Power Monitoring Expert和EcoStruxure Power Operation AdvancedReporting and Dashboards Module都是法国施耐德电气(Schneider Electric)公司的产品。Schneider Electric EcoStruxure Power Monitoring Expert是一个用于物联网环境中进行配电监控的设备。EcoStruxure Power Operation AdvancedReporting and Dashboards Module是一个配电网络定制化组件。 Schneider Electric EcoStruxure Power Monitoring Expert和EcoStruxure Power Operation AdvancedReporting and Dashboards Module存在安全漏洞,该漏洞源于反序列化不可信数据,可能导致远程代码执行和系统完整性受损。
英文描述:
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization.
CWE类型:
标签:
受影响产品
| 厂商 | 产品 | 版本 | 版本范围 | 平台 | CPE |
|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) | Version 2022 | - | - |
cpe:2.3:a:schneider_electric:ecostruxure™_power_monitoring_expert_(pme):version_2022:*:*:*:*:*:*:*
|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) | Version 2023 | - | - |
cpe:2.3:a:schneider_electric:ecostruxure™_power_monitoring_expert_(pme):version_2023:*:*:*:*:*:*:*
|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) | Version 2024 | - | - |
cpe:2.3:a:schneider_electric:ecostruxure™_power_monitoring_expert_(pme):version_2024:*:*:*:*:*:*:*
|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) | Version 2024 R2 | - | - |
cpe:2.3:a:schneider_electric:ecostruxure™_power_monitoring_expert_(pme):version_2024_r2:*:*:*:*:*:*:*
|
| Schneider Electric | EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module | Version 2022 w/ Advanced Reporting Module | - | - |
cpe:2.3:a:schneider_electric:ecostruxure™_power_operation_(epo)_advanced_reporting_and_dashboards_module:version_2022_w__advanced_reporting_module:*:*:*:*:*:*:*
|
| Schneider Electric | EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module | Version 2024 w/ Advanced Reporting Module | - | - |
cpe:2.3:a:schneider_electric:ecostruxure™_power_operation_(epo)_advanced_reporting_and_dashboards_module:version_2024_w__advanced_reporting_module:*:*:*:*:*:*:*
|
解决方案
中文解决方案:
英文解决方案:
临时解决方案:
参考链接
cve.org
CVSS评分详情
4.0 (cna)
HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
时间信息
利用信息
数据源详情
| 数据源 | 记录ID | 版本 | 提取时间 |
|---|---|---|---|
| CVE | cve_CVE-2025-54923 |
2025-11-11 15:23:29 | 2025-11-11 07:40:43 |
| NVD | nvd_CVE-2025-54923 |
2025-11-11 15:01:00 | 2025-11-11 07:48:30 |
| CNNVD | cnnvd_CNNVD-202508-2258 |
2025-11-11 15:12:54 | 2025-11-11 08:00:06 |
版本与语言
安全公告
变更历史
查看详细变更
- vulnerability_type: 未提取 -> 代码问题
- cnnvd_id: 未提取 -> CNNVD-202508-2258
- data_sources: ['cve', 'nvd'] -> ['cnnvd', 'cve', 'nvd']
查看详细变更
- data_sources: ['cve'] -> ['cve', 'nvd']